Thermal Overload Relay JLR2-D13
Karakteristik Gerakan: Wektu Gerakan Keseimbangan Telung Fase
No | Wektu setelan saiki (A) | Wektu gerakan | Kondisi wiwitan | Suhu sekitar | ||
1 | 1.05 | > 2 jam | kahanan kadhemen | 20±5°C
| ||
2 | 1.2 | <2h | Kahanan panas | |||
3 | 1.5 | <4 min | (Sawise tes No.l) | |||
4 | 7.2 | 10A | 2s | <63A | kahanan kadhemen | |
10 | 4s | > 63A |
Karakteristik Gerakan Fase-ilang
No | Wektu setelan saiki (A) | Wektu gerakan | Kondisi wiwitan | Suhu sekitar | |
Sembarang rong fase | Fase liyane | ||||
1 | 1.0 | 0.9 | > 2 jam | kahanan kadhemen | 20±5°C |
2 | 1.15 | 0 | <2h | Kahanan panas (Sawise tes No.l) |
Spesifikasi
Jinis | Nomer | Range setelan (A) | Kanggo kontaktor |
JLR2-D13
| 1301 | 0.1~0.16 | JLC1-09~32 |
1302 | 0.16~0.25 | JLC1-09~32 | |
1303 | 0.25~0.4 | JLC1-09~32 | |
1304 | 0.4~0.63 | JLC1-09~32 | |
1305 | 0.63~1 | JLC1-09~32 | |
1306 | 1~1.6 | JLC1-09~32 | |
1307 | 1.6~2.5 | JLC1-09~32 | |
1308 | 2.5~4 | JLC1-09~32 | |
1310 | 4~6 | JLC1-09~32 | |
1312 | 5.5~8 | JLC1-09~32 | |
1314 | 7~10 | JLC1-09~32 | |
1316 | 9~13 | JLC1-09~32 | |
1321 | 12~18 | JLC1-09~32 | |
1322 | 17~25 | JLC1-32 | |
JLR2-D23
| 2353 | 23~32 | CJX2-09~32 |
2355 | 30~40 | JLC1-09~32 | |
JLR2-D33
| 3322 | 17~25 | JLC1-09~32 |
3353 | 23~32 | JLC1-09~32 | |
3355 | 30~40 | JLC1-09~32 | |
3357 | 37~50 | JLC1-09~32 | |
3359 | 48~65 | JLC1-09~32 | |
3361 | 55~70 | JLC1-09~32 | |
3363 | 63-80 | JLC1-09~32 | |
3365 | 80~93 | JLC1-95 | |
JLR2-D43
| 4365 | 80~104 | JLC1-95 |
4367 | 95~120 | JLC1-95~115 | |
4369 | 110~140 | JLC1-115 |
Outline lan Ukuran Pemasangan
Aksesoris
Skenario aplikasi:
Biasane dipasang ing kothak distribusi ing lantai, pusat komputer, ruang telekomunikasi, ruang kontrol lift, ruang TV kabel, ruang kontrol bangunan, pusat geni, area kontrol otomatis industri, ruang operasi rumah sakit, ruang pemantauan lan peralatan kothak distribusi kanthi piranti medis elektronik .